Page 1 - Sealless Centrifugal Pumps

Assembly, Installation and Operation ManualDB3, 4, 5 & 5.5 Series Sealless Centrifugal Pumps

Page 2

3. To reinstall the original drive or a new drive, follow the in- structions from Section I – Assembly, Pumps without Motors, Steps 4 - 6.Thrust

Page 3 - Table of Contents

Section VII - TroubleshootingGeneral Notes:• Do not pump liquids containing ferrous metal fines.• If magnets decouple, stop pump immediately. Operati

Page 4 - Safety Precautions

Part Number ExplanationDB3, 4, & 5 (1” FNPT x 1/2” MNPT) Base Models DB5.5 (1” FNPT x 3/4” MNPT) Base ModelsPolypropylene ModelsPump End Wet EndDB

Page 5

DB3-4-5-5.5 Spare Parts Drawing10

Page 6 - Section I - Assembly

DB3/4/5/5.5 SPARE PARTS LISTItem Qty DescriptionPump MaterialPolypropylene PVDF1 1Impeller Housing with Thrust Ring & Housing ScrewsDB3/4/5 NPT A1

Page 7 - Mounting

P/N 107599, R4, 5/22/13Lit. ID No. FT10-1123B10 1Drive Lock Washer56 frame 10714163 frame 10632271 frame 10632011 1Drive Flat Washer56 frame 10712563

Page 8 - Section V - Disassembly

EU Declaration of ConformityFinish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requ

Page 9 - Outer Drive Replacement

Table of ContentsImportant Information - Read Me First ...1 Chemical Reaction Disclaimer Safety Precauti

Page 10 - Section VI - Reassembly

IMPORTANT INFORMATION - READ ME FIRST!Model Number and Serial NumberRecord the model number and serial number below for future reference. This is imp

Page 11 - Ordering Spare Parts

Installation/Operation Precautions CAUTION: This pump should never be operated without liquid in the casing. It is recommended that run dry protecti

Page 12 - Part Number Explanation

Section I - AssemblyPumps with MotorsProceed to Installation SectionPumps Without MotorsTools Required: Metric socket set, 7 mm socket (63 frame), 8

Page 13

8. Install the pump end on the motor/drive magnet assembly. Carefully slide the pump onto the drive magnet assembly. See figure 7.9. Secure the

Page 14 - DB3/4/5/5.5 SPARE PARTS LIST

Motor/ElectricalInstall the motor according to NEC requirements and local electri-cal codes. The motor should have an overload protection circuit.Wire

Page 15 - Lit. ID No. FT10-1123B

wear protective clothing, eye protection and follow standard safety procedures when handling corrosive or personally harmful materials. Proper procedu